DC Port

The Wanscale Platform extends to the datacenter through services such as DC Connect and L2 Connect. These services require a physical connection point known as a DC Port.

Supported Datacenters

You can request a DC Port in the following locations:

Datacenter Address
Nikhef Science Park 105, 1098 XG Amsterdam, NL
Datacenter.com Keienbergweg 22, 1101 GB Amsterdam, NL
Digital Realty AMS5 Tupolevlaan 101, 1119 PW Schiphol-Rijk, NL
Digital Realty AMS7 Cessnalaan 50, 1119 NL Schiphol-Rijk, NL
Digital Realty AMS9 Science Park 121, 1098 XG Amsterdam, NL
Equinix AM5 Schepenbergweg 42, 1105 AT Amsterdam, NL
NorthC Rotterdam Waalhaven Anthony Fokkerweg 40, 3088 GG Rotterdam, NL

Info

Talk to Wanscale if your DC is not yet on the list, we are always expanding and might already be near your DC.

Port Specifications

The following port types are available for order. For custom speeds or specific requirements, please contact Wanscale Support.

Speed Type
1 Gbps 10km 1310nm LC-Duplex Singlemode
10 Gbps 10km 1310nm LC-Duplex Singlemode

Info

The Wanscale infrastructure in the datacenters is separated into two availability zones. Maintenance will always be limited to a single zone at a time.

Provisioning Workflow

The diagram below outlines the lifecycle of a DC Port order:

flowchart LR
    A(Ordering DC Port in Portal) --> B(We are notified and assign a port, send a LOA) --> C(Customer installs patch) --> D(CableID is entered in Portal) --> E(Port can be used for services)
    F(We install patch)
    B --> F
    F --> D

    %% Custom style for nodes
    style A fill:#34ebb1
    style B fill:#34ebb1
    style C fill:#34ebb1
    style D fill:#34ebb1
    style E fill:#34ebb1

Ordering a DC Port

Follow these steps to order a new DC Port via the Wanscale Portal:

  1. Navigate to the Home page of the Wanscale Platform.
  2. Click the Add Service button.
  3. Select DC Port from the service list.
  4. Click Go to service form.
  5. Complete the following fields in the service form:
    • Port Label: Enter a descriptive name for the port.
    • Tags (Optional): Add metadata for internal organization.
    • Datacenter: Select your preferred location from the dropdown menu.
    • Speed: Select either 1 Gbps or 10 Gbps.
    • Diversity: Choose an Availability Zone.
  6. Click Submit.

Warning

Redundancy Note: To ensure service redundancy, order multiple DC Ports and assign them to different Availability Zones during the ordering process.

Post-Ordering Instructions

  1. Physical Connection The connection method depends on your specific setup:

    • Standard Connection: If connecting to your own equipment, a physical patch must be installed between the racks. Wanscale will provide a Letter of Authorization (LOA) if you are performing the installation, or Wanscale can perform the install on your behalf.
    • Managed Firewall Connection: If connecting to a Fortigate Firewall hosted in a Wanscale rack, Wanscale will manage the patching automatically.
  2. Port Activation (Turn Up) To transition a DC Port from Ordered to Delivered status, Wanscale requires the CableID from the patch.

    • Current Process: Contact Wanscale to provide your CableID.
    • Future Update: A self-service field to enter the CableID will be added to the portal in a future release.

Technical Verification: If you are on-site for installation, you may call Wanscale during business hours to verify RX/TX and optical values in real-time.

Note

Applying Changes: Like all networking services in the portal, your new DC Port(s) will not be active until you deploy the changes. See Workflows and Applying Changes.